Mechanical behaviour of rammed earth column: A comparison between unreinforced, steel and bamboo reinforced columns
DOI:
https://doi.org/10.3989/mc.2018.11517Keywords:
Portland cement, Steel, Compressive strength, Composite, CuringAbstract
This paper presents an experimental study on the behavior of cement stabilized rammed earth (CSRE) column reinforced with steel under axial loading and its comparison with unreinforced and bamboo reinforced columns. Effects of structural parameters such as tie / stirrup spacing on the failure pattern, lateral and axial deformation of columns are studied. Test results show that the load-capacity of columns increases with increase in lateral / tie reinforcement ratio. Maximum axial and lateral deformations occur in columns with least tie spacing. Behavior of CSRE columns reinforced with close tie spacing is characterized by gradual spalling of cover at the failure zone. Steel reinforced columns perform better than other column types in terms of load-capacity; hence it may be used as structural member adjacent to walls for low-rise rammed earth houses. Proposed reinforcement technique can be adopted in the field for enhancement of greater strength and performance of columns.
Downloads
References
Easton, D. (1982) The rammed earth experience 1st Ed., Blue Mountain Press, Wilseyville, CA, (1982). https://www.amazon.com/Rammed-Earth-Experience-David-Easton/dp/9996936163
Houben, H.; Guillaud, H. (1994) Earth construction- A comprehensive guide. Intermediate Technology Publications, London (1994). https://trove.nla.gov.au/work/10685474?q&versionId=46562438 PMCid:PMC1334437
Walker, P. (1995) Strength, durability and shrinkage characteristics of cement stabilised soil blocks. Cem. Con. Comp. 17 [4], 301–310. https://doi.org/10.1016/0958-9465(95)00019-9
Jayasinghe, C.; Kamaladasa, N. (2007) Compressive strength characteristics of cement stabilized rammed earth walls. Construcc. Build. Mater. 21, 1971–1976. https://doi.org/10.1016/j.conbuildmat.2006.05.049
Ciancio, D.; Beckett, C.; Augarde, C.; Jaquin, P. (2016) First international conference on rammed earth construction: report. Proc. Institu. Civil Engrs. – Construcc. Mater. 169 [5], 271–275. https://doi.org/10.1680/jcoma.15.00038
Reddy, B.V.V.; Leuzinger, G.; Sreeram, V.S. (2014) Low embodied energy cement stabilised rammed earth building—A case study. En. Build. 68, 541–546. https://doi.org/10.1016/j.enbuild.2013.09.051
Bui, Q.B.; Morel, J.C.; Hans, S.; Walker, P. (2014). Effect of moisture content on the mechanical characteristics of rammed earth. Construcc. Build. Mater. 54, 163–169. https://doi.org/10.1016/j.conbuildmat.2013.12.067
Tripura, D.; Singh, K. D. (2014a) Characteristic properties of cement-stabilized rammed earth blocks. J. Mater. Civil Eng. 27 [7].
Tripura, D.; Singh, K.D. (2014b) Behaviour of cement stabilized rammed earth circular column under axial loading. Mater. Struct. 49 [1–2], 371–382.
Tripura, D.; Singh, K. D. (2015) Axial load-capacity of rectangular cement stabilized rammed earth columns. Eng. Struct. 99, 402–412. https://doi.org/10.1016/j.engstruct.2015.05.014
Hall, M.; Djerbib, Y. (2004) Rammed earth sample production: Context, recommendations and consistency. Construcc. Build. Mater. 18 [4], 281–286. https://doi.org/10.1016/j.conbuildmat.2003.11.001
Maniatidis, V.; Walker, P. (2008) Structural capacity of rammed earth in compression. J. Mater. Civil Eng. 20 [3], 230–238. https://doi.org/10.1061/(ASCE)0899-1561(2008)20:3(230)
Burroughs, S. (2008) Soil property criteria for rammed earth stabilisation. J. Mater. Civil Eng. 20 [3].
Reddy, B. V. V.; Kumar, P. P. (2011) Structural behaviour of story-high cement-stabilized rammed earth wall under compression. J. Mater. Civil Eng. 23 [3], 240–247. https://doi.org/10.1061/(ASCE)MT.1943-5533.0000155
Bui, Q.B.; Hans, S.; Morel, J.C.; Do, A.P. (2011) First exploratory study on dynamic characteristics of rammed earth buildings. Eng. Struct. 33 [12], 3690–3695. https://doi.org/10.1016/j.engstruct.2011.08.004
Lindsay, R. (2012) Structural steel elements within stabilized rammed earth walling. –In Modern earth building-materials, engineering, construction and applications, Woodhead Publishing Series in Energy: Number 33, 461–480 (2012).
Ciancio, D.; Augarde, C. (2013) Capacity of unreinforced rammed earth walls subject to lateral wind force: elastic analysis versus ultimate strength analysis. Mater. Struct. 46 [9], 1569–1585. https://link.springer.com/article/10.1617/s11527-012-9998-8 https://doi.org/10.1617/s11527-012-9998-8
Gupta, R. (2014) Characterizing material properties of cement-stabilized rammed earth to construct sustainable insulated walls. J. Case Studies Construcc. Mater. 1, 60–68. https://doi.org/10.1016/j.cscm.2014.04.002
Ngowi, A.B. (1997) Improving the traditional earth construction: a case study of Botswana. Construcc. Build. Mater. 11 [1], 1–7. https://doi.org/10.1016/S0950-0618(97)00006-8
Guettala, A.; Abibsi, A.; Houari, H. (2006) Durability study of stabilized earth concrete under both laboratory and climatic conditions exposure. Construcc. Build. Mater. 20 [3], 119–127. https://doi.org/10.1016/j.conbuildmat.2005.02.001
Tripura, D.; Das, S. (2017) Shape and size effects on the compressive strength of cement stabilised rammed earth. ASCE/Library.
Walker, P. J.; Dobson, S. (2001) Pullout test on deformed and plain rebars in cement-stabilized rammed earth. J. Mater. Civil Eng. 13 [4], 291–297. https://doi.org/10.1061/(ASCE)0899-1561(2001)13:4(291)
Tripura, D.; Sharma, R. (2013) Bond behaviour of bamboo splints in cement-stabilized rammed earth blocks. Inter. J. Sustain. Eng. 7 [1], 24–33. https://doi.org/10.1080/19397038.2012.757671
Miccoli, L.; Müller, U.; Fontana, P. (2014) Mechanical behavior of earthen materials: A comparison between earth block masonry, rammed earth and cob. Construcc. Build. Mater. 61, 327–339. https://doi.org/10.1016/j.conbuildmat.2014.03.009
Ghavami, K. (2005) Bamboo as reinforcement in structural concrete elements. Cem. Conc. Comp. 27 [6], 637–649. https://doi.org/10.1016/j.cemconcomp.2004.06.002
Agarwal, A.; Nanda, B.; Maity, D. (2014) Experimental investigation on chemically treated bamboo reinforced concrete beams and columns. Construcc. Build. Mater. 71, 610–617. https://doi.org/10.1016/j.conbuildmat.2014.09.011
Tripura, D.; Singh, K. D. (2016) Axial load-capacity of bamboo-steel reinforced cement stabilised rammed earth column. Struct. Eng. Inter. (accepted). https://www.researchgate.net/publication/305846198_Axial_load-capacity_of_bamboo-steel_reinforced_cement_stabilised_rammed_earth_column
Gao, Z.; Yang, X.; Tao, Z.; Chen, Z.; Jiao, C. (2009) Experimental study of rammed earth wall with bamboo cane under monotonic horizontal load. J. Kunming University Sci. Tech. 34 [2], 1–4. http://en.cnki.com.cn/Article_en/CJFDTOTAL-KMLG200902015.htm
NZS 4297:1998. Engineering design of earth buildings. Wellington, New Zealand. http://www.eastue.org/project/linea-adobe/norme/NZD4297-1998-Engineering_Design_of_Earth_Buildings.pdf
AS HB 195:2002. Australian earth building handbook."Standards Australia, Sydney, Australia. https:// www.standards.org.au/standards-catalogue/sa-snz/building/bd-083/hb--195-2002
IS 2110:2002. Code of practice for in-situ construction of walls in buildings with soil-cement. New Delhi, India. https://services.bis.gov.in:8071/php/BIS/IndStndrdLocatr/ISDetails.php?ID=ODY1Mg%3D%3D
ASTM E2392/E2392M-10. Standard guide for design of earthen wall building systems. West Conshohocken, PA. https://www.astm.org/Standards/E2392.htm
Clifton. http://rammedearth.info/cliftons-rammed-earth-blog/ravine-rammed-earthhouse/ravine-house-post-2/. Accessed on 18 June 2015.
IS 2720 (1995) Part 4: Specification for methods of test for soils-grain size analysis. New Delhi, India. https://archive.org/details/gov.in.is.2720.4.1985
IS 2720 (1995) Part 5: Determination of liquid and plastic limit. New Delhi, India. https://archive.org/details/gov.in.is.2720.5.1985
IS 2720 (2002) Part 7: Determination of water content-dry density relation using light compaction. New Delhi, India. https://archive.org/details/gov.in.is.2720.7.1980
Bahar, R.; Benazzoung, M.; Kenai, S. (2004) Performance of compacted cement stabilized soil. Cem. Con. Comp. 26, 811–20. https://doi.org/10.1016/j.cemconcomp.2004.01.003
NZS 4298:1998. Materials and workmanship for earth buildings. Wellington, New Zealand. https://shop.standards.govt.nz/catalog/4298%3A1998%28NZS%29/view
IS 8112:1989. Specification for 43 grade ordinary portland cement. New Delhi, India. https://archive.org/details/gov.in.is.8112.1989
IS 1786:1985. Specification for high strength deformed steel bars and wires for concrete reinforcement. New Delhi, India. https://infostore.saiglobal.com/en-au/standards/bis-is-1786-1985-r2004--1056371/
ASTM D698-12. Standard test methods for laboratory compaction characteristics of soil using standard effort. West Conshohocken, PA. https://www.astm.org/Standards/D698
Cusson D.; Paultre, P. (1994) High-strength concrete columns confined by rectangular ties. J. Struct. Eng. 120 [3], 783–804. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:3(783)
Gardner, H.J.; Jacobson, E.R. (1967) Structural behaviour of concrete filled steel tube. J. Amer. Con. Inst. 64 [7], 404–413.
Han, L.H. (2000) Test on concrete filled steel tubular columns with high slenderness ratios. Adv. Struct. Eng. Inter. J. 3 [4], 337–344. https://doi.org/10.1260/1369433001502265
Patton, M.L.; Singh, K.D. (2014) Finite element modelling of concrete-filled lean duplex stainless steel tubular stub columns. Inter. J. Steel Struct. 14 [3], 619–632. https://doi.org/10.1007/s13296-014-3020-y
Published
How to Cite
Issue
Section
License
Copyright (c) 2018 Consejo Superior de Investigaciones Científicas (CSIC)
This work is licensed under a Creative Commons Attribution 4.0 International License.
© CSIC. Manuscripts published in both the printed and online versions of this Journal are the property of Consejo Superior de Investigaciones Científicas, and quoting this source is a requirement for any partial or full reproduction.All contents of this electronic edition, except where otherwise noted, are distributed under a “Creative Commons Attribution 4.0 International” (CC BY 4.0) License. You may read here the basic information and the legal text of the license. The indication of the CC BY 4.0 License must be expressly stated in this way when necessary.
Self-archiving in repositories, personal webpages or similar, of any version other than the published by the Editor, is not allowed.