<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "journalpublishing3.dtd">
<article article-type="research-article" dtd-version="3.0" xml:lang="en" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
	<front>
		<journal-meta>
			<journal-id journal-id-type="publisher-id">MC</journal-id>
			<journal-title-group>
				<journal-title>Materiales de Construcci&#x00F3;n</journal-title>
			</journal-title-group>
			<issn pub-type="epub">0465-2746</issn>
			<publisher>
				<publisher-name>Consejo Superior de Investigaciones Cientificas</publisher-name>
			</publisher>
		</journal-meta>
		<article-meta>
			<article-id pub-id-type="publisher-id">MC201379_e071</article-id>
			<article-id pub-id-type="doi">10.3989/mc.2015.00715</article-id>
			<article-categories>
				<subj-group subj-group-type="heading">
					<subject>Articles</subject>
				</subj-group>
			</article-categories>
			<title-group>
				<article-title>Spalling behavior and residual resistance of fibre reinforced Ultra-High performance concrete after exposure to high temperatures</article-title>
				<trans-title-group xml:lang="es">
					<trans-title>Comportamiento y resistencias mec&#x00E1;nicas residuales de hormigones de ultra altas prestaciones reforzados con fibras tras su exposici&#x00F3;n a altas temperaturas</trans-title>
				</trans-title-group>
				<alt-title alt-title-type="running-head">Spalling behavior and residual resistance of fibre reinforced Ultra-High performance concrete after exposure to high temperatures</alt-title>
			</title-group>
			<contrib-group>
				<contrib contrib-type="author" corresp="yes">
					<name>
						<surname>Xiong</surname>
						<given-names>Ming-Xiang</given-names>
					</name>
					<xref ref-type="corresp" rid="cor1">&#x002A;</xref>
				</contrib>
				<contrib contrib-type="author">
					<name>
						<surname>Richard Liew</surname>
						<given-names>J.Y.</given-names>
					</name>
				</contrib>
			</contrib-group>
			<aff>Department of Civil Engineering, National University of Singapore, (Singapore)</aff>
			<author-notes>
				<corresp id="cor1"><label>&#x002A;</label><email xlink:href="ceexm@nus.edu.sg">ceexm@nus.edu.sg</email>
				</corresp>
			</author-notes>
			<pub-date pub-type="epub">
				<day>31</day>
				<month>12</month>
				<year>2015</year>
			</pub-date>
			<pub-date pub-type="collection">
				<year>2015</year>
			</pub-date>
			<volume>65</volume>
			<issue>320</issue>
			<elocation-id content-type="doi">10.3989/mc.2015.00715</elocation-id>
			<history>
				<date date-type="received">
					<day>17</day>
					<month>01</month>
					<year>2015</year>
				</date>
				<date date-type="accepted">
					<day>07</day>
					<month>05</month>
					<year>2015</year>
				</date>
				<date date-type="Available on line">
					<day>10</day>
					<month>11</month>
					<year>2015</year>
				</date>
			</history>
			<permissions>
				<copyright-statement>&#x00A9; 2015 CSIC</copyright-statement>
				<copyright-year>2015</copyright-year>
				<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/3.0/">
					<license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial (by-nc) Spain 3.0 License.</license-p>
				</license>
			</permissions>
			<abstract>
				<title>ABSTRACT</title>
				<p>Experimental results of spalling and residual mechanical properties of ultra-high performance concrete after exposure to high temperatures are presented in this paper. The compressive strength of the ultra-high performance concrete ranged from 160 MPa&#x223C;185 MPa. This study aimed to discover the effective way to prevent spalling for the ultra-high performance concrete and gauge its mechanical properties after it was subjected to fire. The effects of fiber type, fiber dosage, heating rate and curing condition were investigated. Test results showed that the compressive strength and elastic modulus of the ultra-high performance concrete declined slower than those of normal strength concrete after elevated temperatures. Polypropylene fiber rather than steel fiber was found effective to prevent spalling but affected workability. The effective fiber type and dosage were recommended to prevent spalling and ensure sufficient workability for casting and pumping of the ultra-high performance concrete.</p>
				</abstract>
				<trans-abstract xml:lang="es">
				<title>RESUMEN</title>
				<p><italic>Comportamiento y resistencias mec&#x00E1;nicas residuales de hormigones de ultra altas prestaciones reforzados con fibras tras su exposici&#x00F3;n a altas temperaturas</italic>. En este trabajo se presentan los resultados m&#x00E1;s relevantes del trabajo experimental realizado para valorar la laminaci&#x00F3;n y las propiedades mec&#x00E1;nicas residuales de hormig&#x00F3;n de ultra-altas prestaciones tras su exposici&#x00F3;n a altas temperaturas. La resistencia a la compresi&#x00F3;n del hormig&#x00F3;n de ultra-altas prestaciones oscil&#x00F3; entre 160 MPa&#x223C;185 MPa. El objetivo de este estudio fue descubrir una manera eficaz de prevenir desprendimientos y/o laminaciones en este hormig&#x00F3;n y medir sus propiedades mec&#x00E1;nicas despu&#x00E9;s de ser sometido al fuego. Las variables estudiadas fueron la presencia y dosificaci&#x00F3;n de fibras, velocidad de calentamiento y condiciones de curado. Los resultados mostraron, tras la exposici&#x00F3;n a altas temperaturas, que la resistencia a compresi&#x00F3;n y el m&#x00F3;dulo de elasticidad del hormig&#x00F3;n de ultra-altas prestaciones disminu&#x00ED;an m&#x00E1;s lento que las de un hormig&#x00F3;n con resistencia normal. La fibra de polipropileno result&#x00F3; m&#x00E1;s eficaz para prevenir desprendimientos que la fibra de acero pero la trabajabilidad se vio afectada. Tras el estudio realizado se recomienda el tipo de fibra m&#x00E1;s efectiva y la dosis para evitar desprendimientos y garantizar la suficiente capacidad de trabajo para la puesta en obra y bombeo del hormig&#x00F3;n de ultra-altas prestaciones.</p>
				</trans-abstract>
			<kwd-group xml:lang="en">
			<title>KEYWORDS</title>
				<kwd>High Performance Concrete</kwd>
				<kwd>Temperature</kwd>
				<kwd>Fiber Reinforcement</kwd>
				<kwd>Polymer</kwd>
				<kwd>Mechanical Properties</kwd>
				</kwd-group>
				<kwd-group xml:lang="es">
				<title>PALABRAS CLAVE</title>
				<kwd>Hormig&#x00F3;n de altas prestaciones</kwd>
				<kwd>Temperatura</kwd>
				<kwd>Refuerzo de fibra</kwd>
				<kwd>Pol&#x00ED;meros</kwd>
				<kwd>Resistencias mec&#x00E1;nicas</kwd>
			</kwd-group>
		</article-meta>
	</front>
	<body>
		<sec id="S0001">
			<title>1. INTRODUCTION</title>
			<p>With the development of concrete technology and the availability of variety of materials such as silica fume and high-range water-reducing admixtures, the production of ultra-high performance concrete (UHPC) with compressive strength higher than 160 MPa is possible nowadays. However, the UHPC has been limited to special applications such as offshore and marine structures, industrial floors, pavements, and security barriers, etc. It has not been used in building structures due to concerns on the brittleness and the spalling behavior under fire. These concerns lead to the situations that the current state-of-the art design codes allow the use of concrete only up to C90/105 for concrete structures and C50/C60 for composite structures (<xref ref-type="bibr" rid="CIT0001">1</xref>&#x2013;<xref ref-type="bibr" rid="CIT0004">4</xref>).</p>
			<p>It is well known that high strength concrete (HSC) is prone to spall under high temperatures. The spalling is caused by the thermal stress due to the temperature gradient during heating, and by the splitting force owing to the release of vapor around 100 &#x00B0;C (<xref ref-type="bibr" rid="CIT0005">5</xref>, <xref ref-type="bibr" rid="CIT0006">6</xref>). It is reported that steel fiber or polymer fiber is effective to prevent spalling of the HSC under high temperatures (<xref ref-type="bibr" rid="CIT0007">7</xref>&#x2013;<xref ref-type="bibr" rid="CIT0010">10</xref>). The steel fibers increase the tensile strength and thus resist the thermal stress. The polymer fibers melt after the temperature inside concrete reaches approximately 170 &#x00B0;C. Therefore the built-up vapor pressure is released through the channels left by the melted polymer fibers. The effect of fibers on spalling has not been reported for the UHPC. Since the UHPC is more likely to spall than the HSC, it is necessary to investigate the spalling behavior and provide recommendations for preventing such spalling.</p>
			<p>Residual mechanical properties (compressive strength and elastic modulus) are generally measured after the concrete specimen cools down to room temperature. There are three types of residual properties: unstressed without pre-load, heated-stressed, stressed-heated (<xref ref-type="bibr" rid="CIT0011">11</xref>). The unstressed residual properties are mostly investigated in literature, which are affected by strength, aggregate type, heating rate, cooling rate, cylinder size, etc. Generally, the compressive strength and elastic modulus of HSC are reduced faster than those of normal strength concrete (NSC) after exposed to high temperatures (<xref ref-type="bibr" rid="CIT0012">12</xref>, <xref ref-type="bibr" rid="CIT0013">13</xref>). However, there is little information on the residual resistance of UHPC in literature; the test results presented in this paper are expected to fill the research gap.</p>
			<p>The present study targets to study the spalling behavior of the UHPC when it is exposed to high temperatures up to 800 &#x00B0;C. An effective way for preventing such spalling, meanwhile maintaining the workability, is to be discovered. In pursuit of better assessment on the residual resistance of structural members made from the fiber reinforced UHPC impaired by fire, the mechanical properties such as compressive strength and elastic modulus are to be provided after it is subjected to temperatures of up to 800 &#x00B0;C using various heating rates, fiber dosages, and curing conditions.</p>
		</sec>
		<sec id="S0002">
			<title>2. BASIC MATERIALS</title>
			<p>The basic materials used in this study to produce UHPC were water and Ducorit<sup>&#x00AE;</sup> D4. Ducorit<sup>&#x00AE;</sup> D4 is one of the commercial Ducorit<sup>&#x00AE;</sup> products (see <ext-link ext-link-type="uri" xlink:href="http://www.densit.com/">http://www.densit.com/</ext-link>). It is made from cementitious mineral powder, superplasticizer and fine bauxite aggregates with maximum sizes less than 4.75 mm and 49% less than 0.6 mm. The mixing proportions for the UHPC are shown in <xref ref-type="table" rid="T0001">Table 1</xref> (<xref ref-type="bibr" rid="CIT0014">14</xref>). Workability of the fresh UHPC was tested using the slump flow test in accordance with ASTM C1611/C1611 M-09b. The slump flow spread was 735 mm (<xref ref-type="bibr" rid="CIT0015">15</xref>).
</p>
			<table-wrap id="T0001">
				<label>Table 1</label>
				<caption>
					<p>Mixing proportions of plain UHPC</p>
				</caption>
				<table frame="hsides" rules="groups">
					<thead>
						<tr>
							<th align="center">Water/D4</th>
							<th align="center">Water (kg)</th>
							<th align="center">D4 (kg)</th>
							<th align="center">UHPC Volume (liters)</th>
						</tr>
					</thead>
					<tbody>
						<tr>
							<td align="center">0.076</td>
							<td align="center">1.9</td>
							<td align="center">25</td>
							<td align="center">9.4</td>
						</tr>
					</tbody>
				</table>
			</table-wrap>
		</sec>
		<sec id="S0003">
			<title>3. EFFECTS OF FIBER TYPES ON PREVENTION OF SPALLING</title>
			<sec id="S20004">
				<title>3.1. Experimental program</title>
				<p>Steel and polypropylene (PP) fibers were used in present study. The properties of steel and polypropylene fibers are given in <xref ref-type="table" rid="T0002">Table 2</xref>. Four batches of UHPC mixtures were prepared as follows:
<table-wrap>
						<table frame="void" rules="none">
							<tbody>
								<tr>
									<td align="left">
										<bold>UHPC</bold>:</td>
									<td align="left">Plain concrete without fibers, the room temperature compressive strength was 166.6 MPa; and</td>
								</tr>
								<tr>
									<td align="left"><bold>UHPC-S</bold>:</td>
									<td align="left">Plain concrete with 1.0% steel fibers in terms of volume, the room temperature compressive strength was 170.1 MPa; and</td>
								</tr>
								<tr>
									<td align="left">
										<bold>UHPC-P</bold>:</td>
									<td align="left">Plain concrete with 1.0% PP fibers in terms of volume, the room temperature compressive strength was 144.1 MPa; and</td>
								</tr>
								<tr>
									<td align="left">
										<bold>UHPC-SP</bold>:</td>
									<td align="left">Plain concrete with 0.5% steel fibers and 0.5% PP fibers in terms of volume, the room temperature compressive strength was 155.8 MPa.</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<table-wrap id="T0002">
					<label>Table 2</label>
					<caption>
						<p>Properties of steel fiber and polypropylene fiber</p>
					</caption>
					<table frame="hsides" rules="groups">
						<thead>
							<tr>
								<th align="left">Fiber</th>
								<th align="center">Code/Type</th>
								<th align="center">Diameter (mm)</th>
								<th align="center">Length (mm)</th>
								<th align="center">Density (kg/m<sup>3</sup>)</th>
								<th align="center">Tensile Strength (MPa)</th>
							</tr>
						</thead>
						<tbody>
							<tr>
								<td align="left">Steel</td>
								<td align="center">SF13/80</td>
								<td align="center">0.16</td>
								<td align="center">13</td>
								<td align="center">7850</td>
								<td align="center">2300</td>
							</tr>
							<tr>
								<td align="left">Polypropylene</td>
								<td align="center">Monofilament</td>
								<td align="center">0.03&#x00B1;0.005</td>
								<td align="center">13</td>
								<td align="center">910&#x00B1;0.01%</td>
								<td align="center">&#x2265;450</td>
							</tr>
						</tbody>
					</table>
				</table-wrap>
				<p>Three cylindrical specimens with a diameter of 100 mm and height of 200 mm were cast for each batch. The specimens were cured in lab air for 28 days with plastic sheet covered. The relative humidity of lab air was approximately 85% and the room temperature was around 30 &#x00B0;C at daytime and 25 &#x00B0;C at night. After curing, the specimens were firstly heated up in an electrical oven to a target temperature of 800 &#x00B0;C with a heating rate of 5 &#x00B0;C/min. Then, the target temperature was maintained for 4 hours to reach a uniform temperature distribution inside the specimen. After that, the specimen was kept in oven and cooled down naturally to room temperature. During the process of heating and cooling, the specimen was laterally covered by a steel casing with drilled holes for heat flow.</p>
			</sec>
			<sec id="S20005">
				<title>3.2. Discussions on test results</title>
				<p>There was no spalling observed for specimens of UHPC with PP fibers (UHPC-P, UHPC-SP). However, the specimens of UHPC with steel fibers (UHPC-S) spalled when the temperature inside oven was approximately 490 &#x00B0;C. The spalled specimens are shown in <xref ref-type="fig" rid="F0001">Figure 1</xref>. Although the UHPC specimens with steel fibers spalled, there was little debris blown away laterally. The peripheral concrete was peeled off, but still attached to the core concrete by the steel fibers. The electrical oven was damaged by debris from the top of specimen as shown in <xref ref-type="fig" rid="F0001">Figure 1</xref>. Following the UHPC-S specimen, the UHPC specimen without fibers was heated where the top of steel casing was welded with additional steel plate. The thickness of the steel plate was 1.5 mm. The plain UHPC specimen also spalled and the spalling debris bent the top cover plate and pushed the steel casing to further damage the oven, as shown in <xref ref-type="fig" rid="F0002">Figure 2</xref>. It can be seen that the peripheral concrete was peeled off and broken into pieces, this was different with the steel fiber reinforced specimen. Due to the spalling hazard, the other UHPC-S and the plain UHPC specimens were not heated in case the spalling would further damage the oven. Thus their residual compressive strengths after heating to 800 &#x00B0;C were not measured.</p>
				<fig id="F0001">
					<label>Figure 1</label>
					<caption>
						<p>Spalled UHPC specimens with steel fibers.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g001.tif"/>
				</fig>
				<fig id="F0002">
					<label>Figure 2</label>
					<caption>
						<p>Spalled UHPC specimens without fibers.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g002.tif"/>
				</fig>
				<p>The residual compressive strengths were tested for all the unspalled specimens after cooling down. The residual compressive strengths and their reduction factors which are the ratios between the residual compressive strengths and their counterparts at room temperature are shown in <xref ref-type="table" rid="T0003">Table 3</xref>. As mentioned above, the steel fiber slightly increased the room temperature strength, owing to the confinement effect of the steel fibers which increased the radial and circumferential strengths of the cylindrical specimen. The UHPC with 1.0% of PP fibers or a combination of 0.5% steel fibers and 0.5% PP fibers exhibited lower strengths than that of UHPC without fibers. This was attributed to the effect of PP fibers on workability, resulting in poorer consolidation of the concrete. The difference in residual compressive strengths of UHPC-P and UHPC-SP was approximately 7.5%. Their reduction factors showed the same difference.
</p>
				<table-wrap id="T0003">
					<label>Table 3</label>
					<caption>
						<p>The residual compressive strength of UHPC mixtures after 800 &#x00B0;C</p>
					</caption>
					<table frame="hsides" rules="groups">
						<thead>
							<tr>
								<th align="left"/>
								<th align="center" colspan="2">Strengths (MPa)</th>
								<th align="center"/>
							</tr>
							<tr>
								<th align="left"/>
								<th align="center" colspan="2"><hr/></th>
								<th align="center"/>
							</tr>
							<tr>
								<th align="left">Specimen</th>
								<th align="center">Room temperature</th>
								<th align="center">After 800 &#x00B0;C</th>
								<th align="center">Reduction factor</th>
							</tr>
						</thead>
						<tbody>
							<tr>
								<td align="left">UHPC</td>
								<td align="center">166.6</td>
								<td align="center">Spalling (not heated to 800 &#x00B0;C)</td>
								<td align="center">&#x2013;</td>
							</tr>
							<tr>
								<td align="left">UHPC-S</td>
								<td align="center">170.1</td>
								<td align="center">Spalling (no strength was tested)</td>
								<td align="center">&#x2013;</td>
							</tr>
							<tr>
								<td align="left">UHPC-P</td>
								<td align="center">144.1</td>
								<td align="center">33.8</td>
								<td align="center">0.235</td>
							</tr>
							<tr>
								<td align="left">UHPC-SP</td>
								<td align="center">155.8</td>
								<td align="center">39.8</td>
								<td align="center">0.255</td>
							</tr>
						</tbody>
					</table>
				</table-wrap>
				<p>The test results indicated that the incorporation of steel fibers was not effective to prevent spalling for the UHPC even with dosage of 1.0% by volume. The addition of 1.0% PP fibers was effective. However, the PP fibers affected the strength of the UHPC specimens due to poor workability caused. As recommended in EN 1992-1-2, more than 2 kg/m<sup>3</sup> (0.25% by volume) of monofilament propylene fiber should be included in high strength concrete mixtures to prevent spalling. Hence, 1.0% PP fibers could be too high to achieve good workability. It is necessary to further reduce the PP fiber dosage.</p>
			</sec>
		</sec>
		<sec id="S0006">
			<title>4. EFFECT OF POLYPROPYLENE FIBERS ON PREVENTION OF SPALLING</title>
			<sec id="S20007">
				<title>4.1. Experimental program</title>
				<p>UHPC mixtures with PP fibers and NSC C50 were investigated. The PP fiber dosages were 0, 0.1%, 0.25% and 0.5% in terms of volume. Two heating rates were considered: 5 &#x00B0;C/min and 30 &#x00B0;C/min. NSC C50 was prepared from ordinary Portland cement, sand, coarse aggregates with maximum size 10 mm, and water. The mixing proportions of C50 are shown in <xref ref-type="table" rid="T0004">Table 4</xref>. There was no PP fibers added into the C50. The specimens were also 100&#x00D7;200 mm cylinders. They were covered by plastic sheet and cured in lab air for 28 days. The target temperatures included room temperature (30 &#x00B0;C), 200 &#x00B0;C, 400 &#x00B0;C, 600 &#x00B0;C and 800 &#x00B0;C. The heating and cooling processes were the same as mentioned in <xref ref-type="sec" rid="S20004">Section 3.1</xref>.</p>
				<table-wrap id="T0004">
					<label>Table 4</label>
					<caption>
						<p>The mixing proportions of NSC C50</p>
					</caption>
					<table frame="hsides" rules="groups">
						<thead>
							<tr>
								<th align="left">Water/Cement</th>
								<th align="center">Water<break/>(kg/m<sup>3</sup>)</th>
								<th align="center">Cement<break/>(kg/m<sup>3</sup>)</th>
								<th align="center">Sand<break/>(kg/m<sup>3</sup>)</th>
								<th align="center">Coarse Aggregate<break/>(kg/m<sup>3</sup>)</th>
							</tr>
						</thead>
						<tbody>
							<tr>
								<td align="left">0.5</td>
								<td align="center">225</td>
								<td align="center">450</td>
								<td align="center">625</td>
								<td align="center">1005</td>
							</tr>
						</tbody>
					</table>
				</table-wrap>
			</sec>
			<sec id="S20008">
				<title>4.2. Test observations</title>
				<p>No spalling was observed for any specimens with the PP fibers. This indicates that 0.1% PP fibers is effective to prevent spalling of the UHPC specimens under high temperature up to 800 &#x00B0;C. The UHPC specimens without PP fibers were not heated after 400 &#x00B0;C in case the spalled debris would damage the electrical oven. After heating, standard compression tests were carried out to evaluate the residual compressive strength and residual elastic modulus after the UHPC specimens were naturally cooled down to room temperature. The failure modes of the UHPC specimens subjected to various temperatures and compression are shown in <xref ref-type="fig" rid="F0003">Figure 3</xref>.</p>
				<fig id="F0003">
					<label>Figure 3</label>
					<caption>
						<p>Failure modes after subjected to target temperatures and compression.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g003.tif"/>
				</fig>
				<p>It was observed that the unheated UHPC specimen was crushed into pieces very noisily. However, it exhibited better ductility and lower noise after exposure to the high temperatures. The appearances of the UHPC specimens were different after heated to different target temperatures due to the changes of microstructures.</p>
			</sec>
			<sec id="S20009">
				<title>4.3. Residual compressive strength</title>
				<p>The residual compressive strengths of the UHPC mixtures and NSC C50 are shown in <xref ref-type="table" rid="T0005">Table 5</xref>. Due to running out of the pre-blended mixture, the batch of UHPC with 0.1% PP fibers under heating rate of 30 &#x00B0;C/min was cast using the pre-blended mixture from second shipment. <xref ref-type="table" rid="T0005">Table 5</xref> shows that the room temperature strength from the second shipment was higher than those from the first shipment. In general, the residual compressive strength decreased as the dosage of PP fibers increased for the same testing temperature and heating rate, due to the reduced workability.
</p>
				<table-wrap id="T0005">
					<label>Table 5</label>
					<caption>
						<p>Residual compressive strengths based on fiber dosage and heating rate (MPa)</p>
					</caption>
					<table frame="hsides" rules="groups">
						<thead>
							<tr>
								<th align="left"/>
								<th align="center"/>
								<th align="center"/>
								<th align="center" colspan="2">UHPC with 0.1% fiber</th>
								<th align="center" colspan="2">UHPC with 0.25% fiber</th>
								<th align="center" colspan="2">UHPC with 0.5% fiber</th>
							</tr>
							<tr>
								<th align="left"/>
								<th align="center"/>
								<th align="center"/>
								<th align="center" colspan="2"><hr/></th>
								<th align="center" colspan="2"><hr/></th>
								<th align="center" colspan="2"><hr/></th>
							</tr>
							<tr>
								<th align="left">Temp. (&#x00B0;C)</th>
								<th align="center">UHPC without fiber 5 &#x00B0;C/min</th>
								<th align="center">C50 without fiber 5 &#x00B0;C/min</th>
								<th align="center">5 &#x00B0;C/min</th>
								<th align="center">30 &#x00B0;C/min</th>
								<th align="center">5 &#x00B0;C/min</th>
								<th align="center">30 &#x00B0;C/min</th>
								<th align="center">5 &#x00B0;C/min</th>
								<th align="center">30 &#x00B0;C/min</th>
							</tr>
						</thead>
						<tbody>
							<tr>
								<td align="left">30</td>
								<td align="center">163</td>
								<td align="center">46</td>
								<td align="center">161</td>
								<td align="center">183</td>
								<td align="center">151</td>
								<td align="center">151</td>
								<td align="center">147</td>
								<td align="center">147</td>
							</tr>
							<tr>
								<td align="left">200</td>
								<td align="center">171</td>
								<td align="center">44</td>
								<td align="center">171</td>
								<td align="center">184</td>
								<td align="center">164</td>
								<td align="center">159</td>
								<td align="center">153</td>
								<td align="center">149</td>
							</tr>
							<tr>
								<td align="left">400</td>
								<td align="center">128</td>
								<td align="center">35</td>
								<td align="center">126</td>
								<td align="center">128</td>
								<td align="center">101</td>
								<td align="center">105</td>
								<td align="center">97</td>
								<td align="center">95</td>
							</tr>
							<tr>
								<td align="left">600</td>
								<td align="center">&#x2013;</td>
								<td align="center">19</td>
								<td align="center">74</td>
								<td align="center">80</td>
								<td align="center">59</td>
								<td align="center">60</td>
								<td align="center">52</td>
								<td align="center">55</td>
							</tr>
							<tr>
								<td align="left">800</td>
								<td align="center">&#x2013;</td>
								<td align="center">9</td>
								<td align="center">41</td>
								<td align="center">28</td>
								<td align="center">36</td>
								<td align="center">31</td>
								<td align="center">34</td>
								<td align="center">31</td>
							</tr>
						</tbody>
					</table>
				</table-wrap>
				<p>Compared with the room temperature strength, the residual compressive strength of UHPC slightly increased for temperature at 200 &#x00B0;C, but decreased beyond 200 &#x00B0;C. The reason for the increase of strength at 200 &#x00B0;C is unclear. There are some hypotheses in the literature (<xref ref-type="bibr" rid="CIT0016">16</xref>&#x2013;<xref ref-type="bibr" rid="CIT0018">18</xref>). The prevailing hypothesis is that the increase of strength is attributed to the increase in the forces between the gel particles (Van der Walls forces) due to the water removal and the consequent shrinkage (<xref ref-type="bibr" rid="CIT0019">19</xref>, <xref ref-type="bibr" rid="CIT0020">20</xref>). The decrease of strength at 400 &#x00B0;C, 600 &#x00B0;C, and 800 &#x00B0;C were related with the decomposition of hydration products such as calcium silicate hydrate <bold>(</bold>C-S-H) and calcium hydroxide Ca(OH)<sub>2</sub>, deterioration of aggregates, and cracking due to thermal incompatibility between the aggregate and cement paste which led to stress concentration.</p>
				<p>The residual factor in this paper is defined as the ratio of the compressive strength or elastic modulus after heating divided by its counterpart at room temperature. The residual compressive strength factors of UHPC were larger than those of C50 as shown in <xref ref-type="fig" rid="F0004">Figure 4</xref>. This is due to the fact that the bauxite aggregate in UHPC exhibited better fire resistance than the conventional siliceous aggregate used for C50. There was no increase of strength at 200 &#x00B0;C for C50. This could be related with the water removal which induces shrinkage of concrete while making the microstructure of concrete more porous. Thus, there is a trade-off between the shrinkage and the porosity. The shrinkage increases the Van der Walls forces between gel particles and thus the compressive strength of concrete. However the increase of porosity reduces the strength of concrete. NSC C50 has higher water content than the UHPC. Hence the loss of strength by the increase of porosity overwhelms the increase of strength by shrinkage. As a result, the compressive strength of NSC C50 did not increase at 200 &#x00B0;C.</p>
				<fig id="F0004">
					<label>Figure 4</label>
					<caption>
						<p>Residual compressive strength of UHPC and C50 without PP fiber.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g004.tif"/>
				</fig>
				<p>The effects of PP fiber dosage on the residual compressive strengths of UHPC mixtures are shown in <xref ref-type="fig" rid="F0005">Figure 5</xref> and <xref ref-type="fig" rid="F0006">Figure 6</xref>. At the heating rate of 5 &#x00B0;C/min, the residual compressive strength factors of UHPC with 0.25% and 0.5% PP fiber at 400 &#x00B0;C and 600 &#x00B0;C were lower than those of UHSC with 0.1% PP fiber with a difference of approximately 18%. For the other temperatures, they were very similar. At the heating rate of 30 &#x00B0;C/min, the differences were not significant and the compressive strengths were similar. It could be concluded that the compressive strength was reduced slightly faster as PP fiber dosage increased at heating rate of 5 &#x00B0;C/min, but similar at 30 &#x00B0;C/min.</p>
				<fig id="F0005">
					<label>Figure 5</label>
					<caption>
						<p>Residual compressive strength of UHPC at heating rate of 5 &#x00B0;C/min.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g005.tif"/>
				</fig>
				<fig id="F0006">
					<label>Figure 6</label>
					<caption>
						<p>Residual compressive strength of UHPC at heating rate of 30 &#x00B0;C/min.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g006.tif"/>
				</fig>
				<p>The effects of heating rate on the residual compressive strength are shown in <xref ref-type="fig" rid="F0007">Figure 7</xref>, <xref ref-type="fig" rid="F0008">Figure 8</xref> and <xref ref-type="fig" rid="F0009">Figure 9</xref>. The maximum difference between the residual factors at 5 &#x00B0;C/min and 30 &#x00B0;C/min were 40.3%, 14.3% and 9.2% as the PP fiber dosage increased from 0.1% to 0.5%. The trend showed that the compressive strength of UHPC with 0.1% PP fibers at 30 &#x00B0;C/min was reduced faster than that at 5 &#x00B0;C/min. However as the PP fiber dosage increased, the difference at different heating rates regarding the deterioration of strength was not significant.</p>
				<fig id="F0007">
					<label>Figure 7</label>
					<caption>
						<p>Residual compressive strength of UHPC with 0.1% PP fibers.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g007.tif"/>
				</fig>
				<fig id="F0008">
					<label>Figure 8</label>
					<caption>
						<p>Residual compressive strength of UHPC 0.25% PP fibers.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g008.tif"/>
				</fig>
				<fig id="F0009">
					<label>Figure 9</label>
					<caption>
						<p>Residual compressive strength of UHPC 0.5% PP fibers.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g009.tif"/>
				</fig>
			</sec>
			<sec id="S20010">
				<title>4.4. Residual elastic modulus</title>
				<p>According to ASTM C469-02 (<xref ref-type="bibr" rid="CIT0021">21</xref>), the elastic modulus is the secant modulus between the stress equal to 40% of peak stress and the stress corresponding to strain of 5&#x00D7;10<sup>&#x2212;5</sup>. Generally, the residual elastic modulus decreased with increasing temperature as given in <xref ref-type="table" rid="T0006">Table 6</xref>, there was no increase at 200 &#x00B0;C. This indicates that the shrinkage of UHPC after water removal has minor effect on the elastic modulus since the primary factors affecting the elastic modulus are the type of aggregate and the presence of sustained stress during heating (<xref ref-type="bibr" rid="CIT0022">22</xref>). Comparing the UHPC with the NSC C50 both without addition of PP fibers as shown in <xref ref-type="fig" rid="F0010">Figure 10</xref>, the residual modulus factors of C50 were smaller than those of UHPC at 200 &#x00B0;C and 400 &#x00B0;C. The difference was approximately 13% and 35%, respectively. Similarly, this was attributed to the type of aggregate.
</p>
				<fig id="F0010">
					<label>Figure 10</label>
					<caption>
						<p>Residual elastic modulusi for UHPC and C50 without PP fiber.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g010.tif"/>
				</fig>
				<table-wrap id="T0006">
					<label>Table 6</label>
					<caption>
						<p>Residual elastic modulus (GPa) based on fiber dosage and heating rate</p>
					</caption>
					<table frame="hsides" rules="groups">
						<thead>
							<tr>
								<th align="left"/>
								<th align="center">UHPC without fiber</th>
								<th align="center">C50 without fiber</th>
								<th align="center" colspan="2">UHPC with 0.1% fiber</th>
								<th align="center" colspan="2">UHPC with 0.25% fiber</th>
								<th align="center" colspan="2">UHPC with 0.5% fiber</th>
							</tr>
							
							<tr>
								<th align="left"/>
								<th align="left"><hr/></th>
								<th align="left"><hr/></th>
								<th align="center" colspan="2"><hr/></th>
								<th align="center" colspan="2"><hr/></th>
								<th align="center" colspan="2"><hr/></th>
							</tr>
							<tr>
								<th align="left">Temp. (&#x00B0;C)</th>
								<th align="center">5 &#x00B0;C/min</th>
								<th align="center">5 &#x00B0;C/min</th>
								<th align="center">5 &#x00B0;C/min</th>
								<th align="center">30 &#x00B0;C/min</th>
								<th align="center">5 &#x00B0;C/min</th>
								<th align="center">30 &#x00B0;C/min</th>
								<th align="center">5 &#x00B0;C/min</th>
								<th align="center">30 &#x00B0;C/min</th>
							</tr>
						</thead>
						<tbody>
							<tr>
								<td align="left">30</td>
								<td align="center">60</td>
								<td align="center">27</td>
								<td align="center">61</td>
								<td align="center">65</td>
								<td align="center">54</td>
								<td align="center">54</td>
								<td align="center">53</td>
								<td align="center">53</td>
							</tr>
							<tr>
								<td align="left">200</td>
								<td align="center">58</td>
								<td align="center">22</td>
								<td align="center">56</td>
								<td align="center">61</td>
								<td align="center">51</td>
								<td align="center">47</td>
								<td align="center">52</td>
								<td align="center">43</td>
							</tr>
							<tr>
								<td align="left">400</td>
								<td align="center">32</td>
								<td align="center">10</td>
								<td align="center">28</td>
								<td align="center">30</td>
								<td align="center">24</td>
								<td align="center">22</td>
								<td align="center">24</td>
								<td align="center">20</td>
							</tr>
							<tr>
								<td align="left">600</td>
								<td align="center">&#x2013;</td>
								<td align="center">3</td>
								<td align="center">22</td>
								<td align="center">17</td>
								<td align="center">18</td>
								<td align="center">15</td>
								<td align="center">18</td>
								<td align="center">12</td>
							</tr>
							<tr>
								<td align="left">800</td>
								<td align="center">&#x2013;</td>
								<td align="center">1</td>
								<td align="center">21</td>
								<td align="center">9</td>
								<td align="center">20</td>
								<td align="center">12</td>
								<td align="center">19</td>
								<td align="center">10</td>
							</tr>
						</tbody>
					</table>
				</table-wrap>
				<p>The effects of PP fiber dosage on the residual modulus factors of UHPC mixtures are shown in <xref ref-type="fig" rid="F0011">Figure 11</xref> and <xref ref-type="fig" rid="F0012">Figure 12</xref>. At heat rate of 5 &#x00B0;C/min, no clear difference was observed with regard to the effect of PP fiber dosage. However at heating rate of 30 &#x00B0;C/min, the elastic modulus was reduced faster with the increase of the dosage of PP fiber.</p>
				<fig id="F0011">
					<label>Figure 11</label>
					<caption>
						<p>Residual elastic modulus for UHPC at heating rate of 5 &#x00B0;C/min.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g011.tif"/>
				</fig>
				<fig id="F0012">
					<label>Figure 12</label>
					<caption>
						<p>Residual elastic modulus for UHPC at heating rate of 30 &#x00B0;C/min.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g012.tif"/>
				</fig>
				<p>The effects of heating rate on the residual modulus factors are shown in <xref ref-type="fig" rid="F0013">Figures 13</xref>&#x2013;<xref ref-type="fig" rid="F0015">15</xref>. For PP fiber dosage of 0.1%, the difference between the residual factors at 5 &#x00B0;C/min and 30 &#x00B0;C/min was minimal up to 400 &#x00B0;C. As the PP fiber dosage increased, the said difference became significant. The difference at 600 &#x00B0;C and 800 &#x00B0;C was significant, irrespective of fiber dosage. It could be concluded that the elastic modulus was reduced faster at higher heating rate. The difference between the residual factors of 5 &#x00B0;C/min and 30 &#x00B0;C/min increased as the PP fiber dosage increased.</p>
				<fig id="F0013">
					<label>Figure 13</label>
					<caption>
						<p>Residual elastic modulus for UHPC with 0.1% PP fibers.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g013.tif"/>
				</fig>
				<fig id="F0014">
					<label>Figure 14</label>
					<caption>
						<p>Residual elastic modulus for UHPC with 0.25% PP fibers.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g014.tif"/>
				</fig>
				<fig id="F0015">
					<label>Figure 15</label>
					<caption>
						<p>Residual elastic modulus for UHPC with 0.5% PP fibers.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g015.tif"/>
				</fig>
			</sec>
		</sec>
		<sec id="S0011">
			<title>5. EFFECT OF CURING CONDITION</title>
			<sec id="S20012">
				<title>5.1. Experimental program</title>
				<p>UHPC with 0.1% PP fibers by volume was investigated. The UHPC was made by using the pre-blended mixture from the second shipment as mentioned above. The cylindrical specimens (100&#x00D7;200 mm) were cured in three conditions as follows:
<table-wrap>
						<table frame="void" rules="none">
							<tbody>
								<tr>
									<td align="left">
										<bold>UHPC-D</bold>:&#160;&#160;&#160;&#160;
									</td>
									<td align="left">Bare specimens were cured in open lab air with a relative humidity (RH) of 85% and temperature of 30 &#x00B0;C for daytime and 25 &#x00B0;C for night; and</td>
								</tr>
								<tr>
									<td align="left">
										<bold>UHPC-H</bold>:
									</td>
									<td align="left">Bare specimens were cured in fog room with a constant RH of 100% and temperature of 28 &#x00B0;C; and</td>
								</tr>
								<tr>
									<td align="left">
										<bold>UHPC-S</bold>:
									</td>
									<td align="left">Specimens were sealed with aluminum foil and cured in lab air. The specimens were prepared to reflect the curing condition where UHPC is encased in hollow steel tubes.</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<p>Three cylinders were prepared for each batch. After 28 days curing, the specimens were heated. The heating rate was 30 &#x00B0;C/min. The heating, cooling, and testing procedures were the same with those aforementioned.</p>
			</sec>
			<sec id="S20013">
				<title>5.2. Discussions on test results</title>
				<p>There was no spalling observed during heating for all specimens due to the addition of 0.1% PP fibers. The residual compressive strength and modulus are shown in <xref ref-type="table" rid="T0007">Table 7</xref>. At room temperature, the strength and modulus of UHPC mixtures were not significantly affected by the curing conditions. This might be due to the fact that UHPC is very dense and the permeability is low. Thus, little water was absorbed even cured in fog room for 28 days. Regarding the site inspection during building construction, the test results implicitly indicated that the mechanical properties of UHPC cured in the open environment can be used for the one encased in hollow steel tubular columns. This facilitates site inspection since it is difficult to take out UHPC specimens from the composite columns for static tests.
</p>
				<table-wrap id="T0007">
					<label>Table 7</label>
					<caption>
						<p>Residual compressive strength and residual elastic modulus based on curing conditions</p>
					</caption>
					<table frame="hsides" rules="groups">
						<thead>
							<tr>
								<th align="left"/>
								<th align="center" colspan="2">UHPC-D</th>
								<th align="center" colspan="2">UHPC-H</th>
								<th align="center" colspan="2">UHPC-S</th>
							</tr>
								<tr>
								<th align="left"/>
								<th align="center" colspan="2"><hr/></th>
								<th align="center" colspan="2"><hr/></th>
								<th align="center" colspan="2"><hr/></th>
							</tr>
							<tr>
								<th align="left">Temp. (&#x00B0;C)</th>
								<th align="center">
									<italic>f</italic>
									<sub>ck</sub> (MPa)</th>
								<th align="center">
									<italic>E</italic>
									<sub>c</sub> (GPa)</th>
								<th align="center">
									<italic>f</italic>
									<sub>ck</sub> (MPa)</th>
								<th align="center">
									<italic>E</italic>
									<sub>c</sub> (GPa)</th>
								<th align="center">
									<italic>f</italic>
									<sub>ck</sub> (MPa)</th>
								<th align="center">
									<italic>E</italic>
									<sub>c</sub> (GPa)</th>
							</tr>
						</thead>
						<tbody>
							<tr>
								<td align="left">30</td>
								<td align="center">183</td>
								<td align="center">65</td>
								<td align="center">181</td>
								<td align="center">67</td>
								<td align="center">186</td>
								<td align="center">66</td>
							</tr>
							<tr>
								<td align="left">200</td>
								<td align="center">184</td>
								<td align="center">61</td>
								<td align="center">186</td>
								<td align="center">60</td>
								<td align="center">189</td>
								<td align="center">60</td>
							</tr>
							<tr>
								<td align="left">400</td>
								<td align="center">128</td>
								<td align="center">30</td>
								<td align="center">137</td>
								<td align="center">29</td>
								<td align="center">129</td>
								<td align="center">30</td>
							</tr>
							<tr>
								<td align="left">600</td>
								<td align="center">80</td>
								<td align="center">17</td>
								<td align="center">74</td>
								<td align="center">18</td>
								<td align="center">77</td>
								<td align="center">18</td>
							</tr>
							<tr>
								<td align="left">800</td>
								<td align="center">28</td>
								<td align="center">9</td>
								<td align="center">31</td>
								<td align="center">10</td>
								<td align="center">30</td>
								<td align="center">9</td>
							</tr>
						</tbody>
					</table>
				</table-wrap>
				<p>The residual factors of compressive strength and elastic modulus with various curing conditions are plotted in <xref ref-type="fig" rid="F0016">Figure 16</xref> and <xref ref-type="fig" rid="F0017">Figure 17</xref>. No clear difference was observed with regard to the effects of curing conditions. This is because the residual compressive strength and elastic modulus were measured after the water was removed by heating. Thus the residual properties would be similar regardless of how much water have been absorbed before heating. Comparing the residual factors between the residual compressive strength and the residual elastic modulus as shown in <xref ref-type="fig" rid="F0016">Figure 16</xref> and <xref ref-type="fig" rid="F0017">Figure 17</xref>, the residual modulus was reduced faster under all curing conditions. Especially at 400 &#x00B0;C, the residual elastic modulus was reduced by 55% but 30% for the residual compressive strength. It indicated that the elastic modulus was more sensitive to fire compared with the compressive strength. Thus, the composite columns filled with the UHPC may be more likely governed by buckling failure rather than cross-sectional failure under fire.</p>
				<fig id="F0016">
					<label>Figure 16</label>
					<caption>
						<p>Residual factors of strength under all curing conditions.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g016.tif"/>
				</fig>
				<fig id="F0017">
					<label>Figure 17</label>
					<caption>
						<p>Residual factors of elastic modulus under all curing conditions.</p>
					</caption>
					<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MC201379_e071-g017.tif"/>
				</fig>
			</sec>
		</sec>
		<sec id="S0014">
			<title>6. CONCLUSIONS</title>
			<p>The spalling behavior and residual resistance of ultra-high performance concrete were introduced in this paper. The effective way has been found to prevent spalling of the ultra-high performance concrete through this research. Fiber dosage, heating rate and curing conditions were investigated for the residual resistance of the ultra-high performance concrete specimens. Some main findings can be obtained as follows.<list list-type="order">
					<list-item>
						<p>Steel fiber is not effective to prevent spalling of the ultra-high performance concrete even its dosage is 1.0% by volume. Polypropylene fiber with dosage of 0.1% is found to be effective for temperature up to 800 &#x00B0;C since the polypropylene fibers melt and then leave voids for release of vapor.</p>
					</list-item>
					<list-item>
						<p>Strength of the ultra-high performance concrete at heating rate of 30 &#x00B0;C/min is reduced faster than that at 5 &#x00B0;C/min when the polypropylene fiber dosage is 0.1%. As the polypropylene fiber dosage increases, the reduction is similar at different heating rates. At 5 &#x00B0;C/min, strength is reduced faster as the polypropylene fiber dosage increases. At 30 &#x00B0;C/min, the reduction of strength is similar for various polypropylene fiber dosages.</p>
					</list-item>
					<list-item>
						<p>Elastic modulus of the ultra-high performance concrete is reduced faster at higher heating rate. The difference between residual factors at 5 &#x00B0;C/min and 30 &#x00B0;C/min increases as the polypropylene fiber dosage increases. The polypropylene fiber dosage does not significantly affect the residual modulus factor at 5 &#x00B0;C/min, however at heating rate of 30 &#x00B0;C/min, the elastic modulus is reduced faster with the increase of PP fiber dosage.</p>
					</list-item>
					<list-item>
						<p>There is an increase of strength after exposure to 200 &#x00B0;C, due to the shrinkage by water removal. The increase is not found for elastic modulus.</p>
					</list-item>
					<list-item>
						<p>Strength and elastic modulus of the ultra-high performance concrete are reduced slower after heating than those of C50, due to the fire resistant bauxite aggregate in the ultra-high strength concrete.</p>
					</list-item>
					<list-item>
						<p>Curing condition exhibits insignificant effects on the residual compressive strength and residual elastic modulus of the ultra-high strength concrete. For all curing conditions, the elastic modulus is generally reduced faster than the strength after heating.</p>
					</list-item>
				</list>
			</p>
		</sec>
	</body>
	<back>
	<ack>
			<title>ACKNOWLEDGEMENT</title>
			<p>The authors would like to acknowledge the funding support by Singapore A&#x002A;STAR for research project &#x201C;Steel-concrete composite systems employing ultra-high strength steel and concrete for sustainable high-rise construction&#x201D; under SERC Grant No: 092 142 0045.</p>
		</ack>
		<ref-list>
			<title>REFERENCES</title>
			<ref id="CIT0001">
				<label>1</label>
				<nlm-citation publication-type="gov">
					<collab>EN 1992-1-1</collab>
					<article-title>Eurocode 2: Design of concrete structures - Part 1-1: General rules and rules for buildings</article-title>
					<source>European Committee for Standardization</source>
					<year>2004</year>
				</nlm-citation>
			</ref>
			<ref id="CIT0002">
				<label>2</label>
				<nlm-citation publication-type="gov">
					<collab>EN 1992-1-2</collab>
					<article-title>Eurocode 2: Design of concrete structures - Part 1-2: General rules-structural fire design</article-title>
					<source>European Committee for Standardization</source>
					<year>2004</year>
				</nlm-citation>
			</ref>
			<ref id="CIT0003">
				<label>3</label>
				<nlm-citation publication-type="gov">
					<collab>EN 1994-1-1</collab>
					<article-title>Eurocode 4: Design of composite steel and concrete structures - Part 1-1: General rules and rules for buildings</article-title>
					<source>European Committee for Standardization</source>
					<year>2004</year>
				</nlm-citation>
			</ref>
			<ref id="CIT0004">
				<label>4</label>
				<nlm-citation publication-type="gov">
					<collab>EN 1994-1-2</collab>
					<article-title>Eurocode 4: Design of composite steel and concrete structures - Part 1-2: General rules - Structural fire design</article-title>
					<source>European Committee for Standardization</source>
					<year>2005</year>
				</nlm-citation>
			</ref>
			<ref id="CIT0005">
				<label>5</label>
				<nlm-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ali</surname>
							<given-names>F.A.</given-names>
						</name>
						<name>
							<surname>Connor</surname>
							<given-names>D.O.</given-names>
						</name>
						<name>
							<surname>Tair</surname>
							<given-names>A.A.</given-names>
						</name>
					</person-group>
					<article-title>Explosive spalling of high-strength concrete columns in fire</article-title>
					<source>Mag. Concr. Res.</source>
					<year>2001</year>
					<volume>53</volume>
					<issue>3</issue>
					<fpage>197</fpage>
					<lpage>204</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1680/macr.2001.53.3.197">http://dx.doi.org/10.1680/macr.2001.53.3.197</ext-link>.</comment>
				</nlm-citation>
			</ref>
			<ref id="CIT0006">
				<label>6</label>
				<nlm-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ko</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Ryu</surname>
							<given-names>D.</given-names>
						</name>
						<name>
							<surname>Noguchi</surname>
							<given-names>T.</given-names>
						</name>
					</person-group>
					<article-title>The spalling mechanism of high-strength concrete under fire</article-title>
					<source>Mag. Concr. Res.</source>
					<year>2011</year>
					<volume>63</volume>
					<issue>5</issue>
					<fpage>357</fpage>
					<lpage>370</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1680/macr.10.00002">http://dx.doi.org/10.1680/macr.10.00002</ext-link>.</comment>
				</nlm-citation>
			</ref>
			<ref id="CIT0007">
				<label>7</label>
				<nlm-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Chen</surname>
							<given-names>B.</given-names>
						</name>
						<name>
							<surname>Liu</surname>
							<given-names>J.Y.</given-names>
						</name>
					</person-group>
					<article-title>Residual strength of hybrid-fiber-reinforced high-strength concrete after exposure to high temperatures</article-title>
					<source>Cem. Concr. Res.</source>
					<year>2004</year>
					<volume>34</volume>
					<issue>6</issue>
					<fpage>1065</fpage>
					<lpage>1069</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.cemconres.2003.11.010">http://dx.doi.org/10.1016/j.cemconres.2003.11.010</ext-link>.</comment>
				</nlm-citation>
			</ref>
			<ref id="CIT0008">
				<label>8</label>
				<nlm-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Han</surname>
							<given-names>C.C.</given-names>
						</name>
						<name>
							<surname>Hwang</surname>
							<given-names>Y.S.</given-names>
						</name>
						<name>
							<surname>Yang</surname>
							<given-names>S.H.</given-names>
						</name>
						<name>
							<surname>Gowripalan</surname>
							<given-names>N.</given-names>
						</name>
					</person-group>
					<article-title>Performance of spalling resistance of high performance concrete with polypropylene fiber contents and lateral confinement</article-title>
					<source>Cem. Concr. Res.</source>
					<year>2005</year>
					<volume>35</volume>
					<issue>9</issue>
					<fpage>1747</fpage>
					<lpage>1753</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.cemconres.2004.11.013">http://dx.doi.org/10.1016/j.cemconres.2004.11.013</ext-link>.</comment>
				</nlm-citation>
			</ref>
			<ref id="CIT0009">
				<label>9</label>
				<nlm-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Zeiml</surname>
							<given-names>M.</given-names>
						</name>
						<name>
							<surname>Leithner</surname>
							<given-names>D.</given-names>
						</name>
						<name>
							<surname>Lackner</surname>
							<given-names>R.</given-names>
						</name>
						<name>
							<surname>Mang</surname>
							<given-names>H.A.</given-names>
						</name>
					</person-group>
					<article-title>How do polypropylene fibers improve the spalling behavior of in-situ concrete?</article-title>
					<source>Cem. Concr. Res.</source>
					<year>2006</year>
					<volume>36</volume>
					<issue>5</issue>
					<fpage>929</fpage>
					<lpage>942</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.cemconres.2005.12.018">http://dx.doi.org/10.1016/j.cemconres.2005.12.018</ext-link>.</comment>
				</nlm-citation>
			</ref>
			<ref id="CIT0010">
				<label>10</label>
				<nlm-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Hadi</surname>
							<given-names>M.N.S.</given-names>
						</name>
					</person-group>
					<article-title>Using fibres to enhance the properties of concrete columns</article-title>
					<source>Constr. Build. Mater.</source>
					<year>2007</year>
					<volume>21</volume>
					<issue>1</issue>
					<fpage>118</fpage>
					<lpage>125</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.conbuildmat.2005.06.028">http://dx.doi.org/10.1016/j.conbuildmat.2005.06.028</ext-link>.</comment>
				</nlm-citation>
			</ref>
			<ref id="CIT0011">
				<label>11</label>
				<nlm-citation publication-type="journal">
						<collab>RILEM Technical Committee</collab>
					<article-title>Recommendation of RILEM TC 200-HTC: mechanical concrete properties at high temperatures &#x2013; modeling and applications, Part 2: stress-strain relation</article-title>
					<source>Mater. Struct.</source>
					<year>2007</year>
					<volume>40</volume>
					<issue>9</issue>
					<fpage>855</fpage>
					<lpage>864</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1617/s11527-007-9286-1">http://dx.doi.org/10.1617/s11527-007-9286-1</ext-link>.</comment>
				</nlm-citation>
			</ref>
			<ref id="CIT0012">
				<label>12</label>
				<nlm-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>Morita</surname>
							<given-names>T.</given-names>
						</name>
						<name>
							<surname>Saito</surname>
							<given-names>H.</given-names>
						</name>
						<name>
							<surname>Kumagai</surname>
							<given-names>H.</given-names>
						</name>
					</person-group>
					<source>Residual mechanical properties of high strength concrete members exposed to high temperature - Part 1: Test on material properties</source>
					<year>1992</year>
					<conf-name>Summaries of Technical Papers of Annual Meeting</conf-name>
					<conf-loc>Architectural Institute of Japan, Niigata</conf-loc>
				</nlm-citation>
			</ref>
			<ref id="CIT0013">
				<label>13</label>
				<nlm-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>Felicetti</surname>
							<given-names>R.</given-names>
						</name>
						<name>
							<surname>Gambarova</surname>
							<given-names>P.G.</given-names>
						</name>
						<name>
							<surname>Rosati</surname>
							<given-names>G.P.</given-names>
						</name>
						<name>
							<surname>Corsi</surname>
							<given-names>F.</given-names>
						</name>
						<name>
							<surname>Giannuzzi</surname>
							<given-names>G.</given-names>
						</name>
					</person-group>
					<source>Residual mechanical properties of high strength concretes subjected to high temperature cycles</source>
					<year>1996</year>
					<conf-name>Proceedings of 4 th International Symposium on Utilization of High Strength/High Performance Concrete</conf-name>
					<conf-loc>Paris France</conf-loc>
					<fpage>579</fpage>
					<lpage>588</lpage>
				</nlm-citation>
			</ref>
			<ref id="CIT0014">
				<label>14</label>
				<nlm-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Liew</surname>
							<given-names>J.Y.R.</given-names>
						</name>
						<name>
							<surname>Xiong</surname>
							<given-names>D.X.</given-names>
						</name>
					</person-group>
					<article-title>Ultra-high strength concrete filled composite columns for multi-storey building construction</article-title>
					<source>Adv. Struct. Eng.</source>
					<year>2012</year>
					<volume>15</volume>
					<issue>9</issue>
					<fpage>1487</fpage>
					<lpage>1503</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1260/1369-4332.15.9.1487">http://dx.doi.org/10.1260/1369-4332.15.9.1487</ext-link>.</comment>
				</nlm-citation>
			</ref>
			<ref id="CIT0015">
				<label>15</label>
				<nlm-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Xiong</surname>
							<given-names>D.X.</given-names>
						</name>
					</person-group>
					<source>Structural behaviour of concrete filled steel tubes with high strength materials</source>
					<year>2012</year>
					<publisher-name>National University of Singapore</publisher-name>
					<comment>PhD thesis</comment>
				</nlm-citation>
			</ref>
			<ref id="CIT0016">
				<label>16</label>
				<nlm-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Dias</surname>
							<given-names>W.P.S.</given-names>
						</name>
						<name>
							<surname>Khoury</surname>
							<given-names>G.A.</given-names>
						</name>
						<name>
							<surname>Sullivan</surname>
							<given-names>P.J.E.</given-names>
						</name>
					</person-group>
					<article-title>Mechanical properties of hardened cement paste exposed to temperatures up to 700 &#x00B0;C</article-title>
					<source>ACI Mater. J.</source>
					<year>1990</year>
					<volume>87</volume>
					<issue>2</issue>
					<fpage>160</fpage>
					<lpage>166</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.14359/1981">http://dx.doi.org/10.14359/1981</ext-link>.</comment>
				</nlm-citation>
			</ref>
			<ref id="CIT0017">
				<label>17</label>
				<nlm-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Khoury</surname>
							<given-names>G.A.</given-names>
						</name>
					</person-group>
					<article-title>Compressive strength of concrete at high temperature: a reassessment</article-title>
					<source>Mag. Concr. Res.</source>
					<year>1992</year>
					<volume>44</volume>
					<issue>161</issue>
					<fpage>291</fpage>
					<lpage>309</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1680/macr.1992.44.161.291">http://dx.doi.org/10.1680/macr.1992.44.161.291</ext-link>.</comment>
				</nlm-citation>
			</ref>
			<ref id="CIT0018">
				<label>18</label>
				<nlm-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Tanyildizi</surname>
							<given-names>H.</given-names>
						</name>
						<name>
							<surname>Coskun</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<article-title>The effect of high temperature on compressive strength and splitting tensile strength of structural lightweight concrete containing fly ash</article-title>
					<source>Constr. Build. Mater.</source>
					<year>2008</year>
					<volume>22</volume>
					<issue>11</issue>
					<fpage>2269</fpage>
					<lpage>2275</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.conbuildmat.2007.07.033">http://dx.doi.org/10.1016/j.conbuildmat.2007.07.033</ext-link>.</comment>
				</nlm-citation>
			</ref>
			<ref id="CIT0019">
				<label>19</label>
				<nlm-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Castillo</surname>
							<given-names>C.</given-names>
						</name>
						<name>
							<surname>Durrani</surname>
							<given-names>A.J.</given-names>
						</name>
					</person-group>
					<article-title>Effect of transient high temperature on high strength concrete</article-title>
					<source>ACI Mater. J.</source>
					<year>1990</year>
					<volume>87</volume>
					<issue>1</issue>
					<fpage>47</fpage>
					<lpage>53</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.14359/2356">http://dx.doi.org/10.14359/2356</ext-link>.</comment>
				</nlm-citation>
			</ref>
			<ref id="CIT0020">
				<label>20</label>
				<nlm-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Behnood</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Ziari</surname>
							<given-names>H.</given-names>
						</name>
					</person-group>
					<article-title>Effects of silica fume addition and water to cement ratio on the properties of high-strength concrete after exposure to high temperatures</article-title>
					<source>Cem. Concr. Compos.</source>
					<year>2008</year>
					<volume>30</volume>
					<issue>2</issue>
					<fpage>106</fpage>
					<lpage>112</lpage>
					<comment>
						<ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.cemconcomp.2007.06.003">http://dx.doi.org/10.1016/j.cemconcomp.2007.06.003</ext-link>.</comment>
				</nlm-citation>
			</ref>
			<ref id="CIT0021">
				<label>21</label>
				<nlm-citation publication-type="gov">
					<collab>ASTM C 469-02</collab>
					<source>Standard test method for static modulus of elasticity and Poisson&#x0027;s ratio of concrete in compression</source>
					<year>2002</year>
					<publisher-loc>United States</publisher-loc>
					<publisher-name>ASTM International</publisher-name>
				</nlm-citation>
			</ref>
			<ref id="CIT0022">
				<label>22</label>
				<mixed-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Naus</surname>
							<given-names>D.J.</given-names>
						</name>
					</person-group>
					<chapter-title>The effect of elevated temperature on concrete material and structures - a literature review</chapter-title>
					<source>Oak Ridge National Laboratory, U.S. Nuclear Regulatory Commision</source>
					<year>2006</year>
					<publisher-loc>Washington DC</publisher-loc>
					<publisher-name>Office of Nuclear Regulatory Research</publisher-name>
				</mixed-citation>
			</ref>
		</ref-list>
	</back>
</article>