Capillarity test monitored by X-ray computer tomography in sandstones. A comparative study with standard methods
DOI:
https://doi.org/10.3989/mc.2008.v58.i289-290.79Keywords:
X-rays, tomography, capillarity, rocks, La Marina sandstoneAbstract
Computerized axial tomography studies were conducted to analyze water movements inside rocks (specifically in La Marina sandstone, used to build some of the historic monuments in Asturias, northern Spain). The X-ray images of water uptake by the stone interior recorded during capillarity tests provided supplementary information not furnished by conventional methods. The three-dimensional images obtained showed the position of the water front over time and its relationship to rock petrography. The volume of water-soaked rock proved to be a more realistic measure of stone capillarity. The results obtained were compared to mean capillarity measured as recommended in Spanish and European standard UNE-EN 1925:1999.
Downloads
References
(1) M. Mamillan: “Connaissances actualles des problémes de remontées d’eau par capillarité dans les murs“. In : R. Rossi-Manaresi (Ed.). The Conservation of Stone II. Proc. Int. Symp. Bologna (Italy), 1981, pp. 73-90.
(2) O. Sass: “ Rock moisture measurements: techniques, results, and implications for weathering”. Earth surface processes and landforms. Vol. 30 (2005), pp. 359-374. doi:10.1002/esp.1214
(3) UNE-EN 1925:1999. Métodos de ensayo para piedra natural. Determinación del coeficiente de absorción de agua por capilaridad. AENOR (Eds.), Madrid, Spain, 1999. 13 pp.
(4) G. Torraca: “Porous building materials”. ICCROM, Technical Notes. Roma (Italy), 1986, 149 pp.
(5) L.B. Wang, J.D. Frost, J.S. Lai: “Three-dimensional digital representation of granular material microstructure from x-ray tomography imaging”. J. of Computing in Civil Engineering. Vol. 18 (2004), pp. 28-35. doi:10.1061/(ASCE)0887-3801(2004)18:1(28)
(6) R.I. Al-Raoush, C. S. Willson: “Extraction of physically realistic pore network properties from three-dimensional synchrotron X-ray microtomography images of unconsolidated porous media systems”. J. of Hydrology. Vol. 300 (2005), pp. 44-64. doi:10.1016/j.jhydrol.2004.05.005
(7) T. Hirono, M. Takahashis, S. Nakashima: “In situ visualization of fluid flow image within deformed rock by X-ray CT”. Eng. Geol. Vol. 70 (2003), pp. 37-46. doi:10.1016/S0013-7952(03)00074-7
(8) V.G. Ruiz de Argandoña, A. Rodríguez-Rey, C. Celorio, L. Calleja, L.M. Suárez del Río: “Characterization by X-ray computed tomography of water absorption in a limestone used as building stone in the Oviedo Cathedral (Spain)”. In: Mess, F. Swennen, R., Van Geet, M., Jacobs, P. (Eds.). Applications of X-ray Computed Tomography in the Geosciences. Geol. Soc., London, Special Publications, 215, 2003, pp.127-134.
(9) Y. Géraud, F. Surma, F. Mazerolle: “Porosity and fluid characterization of granite by capillary wetting using X-ray computed tomography”. In: F. Mess, R. Swennen, M. Van Geet, P. Jacobs, (Eds.). Applications of X-ray Computed Tomography in the Geosciences. Geological Society, London, Special Publications, 215, 2003, pp.95-105.
(10) B. Rousset-Tournier, F. Mazerolle, Y. Géraud, D. Jeannette: “Rock drying test monitored by X-ray computed tomography the effect of saturation methods on drying behaviour”. In: F. Mess, R. Swennen, M. Van Geet, P. Jacobs, (Eds.). Applications of X -ray Computed Tomography in the Geosciences. Geological Society, London, Special Publications, 215, 2003, pp.117-125.
(11) T. Seiki, O. Ayda: “Deterioration of aya tuff and its mechanical property change as building stone”. In: Yüzer, E., Ergin, H., Tugrul, A.(Eds.), Proceedings of the International Symposium Industrial Minerals and Building Stones (IMBS _2003), Istanbul, Turkey, International Association for Engineering Geology and the Environment, The Turkish National Group of IAEG, Istanbul Technical University, 2003, pp. 329-336.
(12) V. Cnudde, P. Jacobs: “Preliminary results of X-ray micro-tomography applied in conservation and restoration of natural building stones”. In: J. Otani, Y. Obara, (Eds.). Proceedings of the International Workshop on X-Ray CT for Geomaterials, GEOX2003. AA Balkema Publishers, Netherlands, 2004. pp. 363-371.
(13) V.G. Ruiz de Argandoña, A. Rodríguez-Rey, C. Celorio, L.M. Suárez del Río, L. Calleja, J. Llavona: “Characterization by computed X-ray tomography of the evolution of the pore structure of a dolomite rock during freeze-thaw cyclic test”. Phys. Chem. Earth (A), Vol. 24 (7), (1999), pp. 633-637. doi:10.1016/S1464-1895(99)00092-7
(14) A. Rodríguez-Rey,V.G. Ruiz de Argandoña, L. Calleja, L.M. Suárez del Río y C. Celorio: “X-ray tomography characterization of microfissuration on rocks generated by freeze-thaw cycles”. In: J. Otani, Y. Obara, (Eds.). Proceedings of the International Workshop on X-Ray CT for Geomaterials, GEOX2003. AA Balkema Publishers, Netherlands, 2004. pp. 293-298.
(15) A. Rodríguez-Rey,V.G. Ruiz de Argandoña, L. Calleja, L.M. Suárez del Río y C. Celorio: “Consolidants influence on sandstone capillarity. X-ray CT study”. In: J. Desrues, G. Viaggiani, O. Bésuelle, (Eds.). Proceedings of the International Workshop on Advances in X-ray Tomography for Geomaterials GEOX2006. ISTE, Ltd., UK, 2006. pp. 381-387.
(16) Geological Society of America: “Rock-Color Chart (with genuine Munsell color chips)”. The Geological Society of America, Boulder, Colorado, 1991.
(17) F.J. Pettijhon, P.E. Potter. R. Siever. SAND AND SANDSTONE. Springer-Verlag, Berlín, 1972, 618 pp.
(18) L.M. Suárez del Río, L. Calleja, I. Díez Sarriá, V.G. Ruiz de Argandoña, A. Rodríguez-Rey: “Características tecnológicas de las rocas ornamentales de Asturias”. Trabajos de Geología. Univ. de Oviedo, Vol. 23 (2002), pp. 73-84.
(19) UNE-EN 1936: 1999. Métodos de ensayo para piedra natural. Determinación de la densidad real y aparente y de la porosidad total y abierta. AENOR (Eds.), Madrid, Spain, 1999. 12 pp.
(20) O.G. Duliu: “Computer axial tomography in geosciences: an overview”. Earth-Science Reviews. Vol. 48 (1999), pp. 265-281. doi:10.1016/S0012-8252(99)00056-2
(21) H. J. G. Gundersen, E. B. Jensen: “The efficiency of systematic sampling in stereology and its prediction”. J. of Microsc., Vol. 147, Pt. 3 (1987), pp. 229-263.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2008 Consejo Superior de Investigaciones Científicas (CSIC)

This work is licensed under a Creative Commons Attribution 4.0 International License.
© CSIC. Manuscripts published in both the print and online versions of this journal are the property of the Consejo Superior de Investigaciones Científicas, and quoting this source is a requirement for any partial or full reproduction.
All contents of this electronic edition, except where otherwise noted, are distributed under a Creative Commons Attribution 4.0 International (CC BY 4.0) licence. You may read here the basic information and the legal text of the licence. The indication of the CC BY 4.0 licence must be expressly stated in this way when necessary.
Self-archiving in repositories, personal webpages or similar, of any version other than the final version of the work produced by the publisher, is not allowed.