The use of electrical resistivity measurement as a non-destructive test in precast concrete sleepers’ production
DOI:
https://doi.org/10.3989/mc.2025.391824Keywords:
concrete, railway sleeper, electrical resistivity, non-destructive test, industrial productionAbstract
In the production of concrete sleepers, it is common to verify that the concrete has the necessary strength for prestress forces release by testing cylinders cured at equivalent conditions. Considering that electrical resistivity measurements may assess the pore structure evolution of concrete, this study proposes the use of this technique to estimate concrete strength evolution at factory conditions. The use of non-destructive testing methods considerably simplifies and modernizes the industrial process, leading to a reduction in labor time and waste. This paper presents a testing protocol aimed at obtaining correlation graphs between concrete compressive strength and electrical conductivity. As the temperature, size and shape of samples may be variable, this paper also presents an innovative procedure to assess correction factors. This procedure is suitable when the liquid water content is high enough not to influence the resistivity measurement. The proposed method was validated at a factory, showing a high correlation.
Downloads
References
Taherinezhad J, Sofi M, Mendis PA., Ngo T. 2013. A review of the behaviour of Prestressed Concrete Sleepers. Electron. J. Struct. Eng. 13(1):1-16. https://doi.org/10.56748/ejse.131571
CEN. 2016a. EN 13230-1:2016 - Railway applications. Track. Concrete sleepers and bearers. Part 1: General requirements.
CEN. 2016b. EN 13230-2:2016 - Railway applications. Track. Concrete sleepers and bearers. Part 2: Prestressed monoblock sleepers
CEN. 2020. EN 13230-6:2020 - Railway applications. Track. Concrete sleepers and bearers. Part 6: Design
Australian Standards. 2019. AS 1085.14. Railway track material, Part 14: Prestressed concrete sleeper.
ABNT. 2015. ABNT NBR 11709-2015 - Concrete sleepers: Design, materials, and components.
AREMA. 2017. Manual for Railway Engineering, Chapter 30, Part 4: Concrete ties.
CCNN-TF. 2023. PROY-NOM-001-ARTF-2023 - Railway System - Infrastructure - Monoblock sleepers - Testing requirements and methodologies.
IRAM. 2019. IRAM 1609-1 - Concrete Sleepers. Prestressed monoblock concrete sleepers. Part 1 - Testing requirements and methodologies
IRAM. 2023. IRAM 1609-2 - Concrete Sleepers. Prestressed monoblock concrete sleepers. Part 2 - Conformity assessment.
Zeyad AM, Tayeh BA, Adesina A, Azevedo ARG, Amin M, Hadzima-Nyarko M, Agwa IS. 2022. Review on effect of steam curing on behavior of concrete. Clean. Mater. 3:100042. https://doi.org/10.1016/j.clema.2022.100042
Nithursham M, Elakneswaran Y. 2023. A systematic review and assessment of concrete strength prediction models. Case Stud. Constr. Mater. 18:e01830. https://doi.org/10.1016/j.cscm.2023.e01830
United Nations Environment Programme, & Yale Center for Ecosystems + Architecture. 2023. Build. Mater. Clim: Constr. New Fut. Retrieved from https://wedocs.unep.org/20.500.11822/43293
Global ABC, IEA and UNEP. 2020 GlobalABC Regional roadmap for buildings and construction in Latin America 2020-2050, IEA, Paris. Retrieved from https://www.iea.org/reports/globalabc-regional-roadmap-for-buildings-and-construction-in-latin-america-2020-2050
Rempelos G, Preston J, Blainey S. 2020. A carbon footprint analysis of railway sleepers in the United Kingdom. Transport Research Part D: Transport and Environment. 81:102285. https://doi.org/10.1016/j.trd.2020.102285
Werner F. 2009. Life cycle assessment (LCA) of railway sleepers, comparison of railway sleepers made from concrete, steel, beech wood and oak wood.
Quick JTK, Dekker E, Montforts MHMM. 2020. Safety and sustainability analysis of railway sleepers alternatives. National Institute for Public Health and the Environment.
Kiani M, Ceney H, Parry T. 2008. Environmental life-cycle assessment of railway track beds. Proceedings of the Institute of Civil Engineers: Engineering Sustainability. 161(2):135-142. https://doi.org/10.1680/ensu.2008.161.2.135
Hammond G, Jones C. 2008. Embodied energy and carbon in construction materials. Inventory of Carbon & Energy (ICE). Proceedings of the Institution of Civil Engineers - Energy. 161(2):87-98. https://doi.org/10.1680/ener.2008.161.2.87
Torrent R, Scrivener K, Fernandez Luco L. 2016. From microstructure to service life design, A Theoretical-Practical RILEM international workshop. International RILEM Conference on Materials, Systems and Structures in Civil Engineering. Conference segment on Teaching. 22-24 August 2016, Technical University of Denmark, Lyngby, Denmark.
Silva PC, Ferreira RM, Figueiras H. 2012. Electrical resistivity as a mean of quality control of concrete - influence of test procedure. XII International Conference of Durability of Building and Materials and Components, Porto - Portugal.
Andrade C, D'Andrea R. 2011. La resistividad como parámetro de control del hormigón y de su durabilidad. Revista de la Asociación Latinoamericana de Control de Calidad, Patología y Recuperación de la Construcción. 1(2):93-101. https://doi.org/10.21041/ra.v1i2.8
Azarsa P, Gupta R. 2017. Electrical resistivity of concrete for durability evaluation: a review. Adv. Mater. Sci. Eng. 1:1-30. https://doi.org/10.1155/2017/8453095
Wenner F. 1915. A Method of measuring earth resistivity. Journal of the Washington Academy of Science. 5(16):561-563. Retrieved from https://nvlpubs.nist.gov/nistpubs/bulletin/12/nbsbulletinv12n4p469_a2b.pdf
AENOR. 2023. Norma UNE-EN 12390-19:2023 - Ensayos de hormigón endurecido. Parte 19: Determinación de la resistividad eléctrica.
D'Andrea R. 2010. Predicción de la durabilidad del hormigón armado a partir de indicadores de corrosión: aplicación de resistividad eléctrica. PhD Thesis, Universidad Politécnica de Madrid - Escuela Técnica Superior de Ingenieros de Caminos, Canales y Puertos.
Fernandez Luco L. 2008. Valoración de técnicas no destructivas para el control de la eficiencia de cursado del hormigón. PdD Thesis, Universidad de Alicante.
Presuel-Moreno F, Liu Y. 2012. Temperature effect on electrical resistivity measurement on mature saturated concrete. NACE - International Corrosion Conference Series. https://doi.org/10.5006/C2012-01732
AENOR. 2016. UNE-EN 13230-1:2016. Aplicaciones ferroviarias, vía, traviesas y soportes de hormigón, Parte 1: Requisitos Generales.
Morris W, Moreno EI, Sagiiés AA. 1996. Practical evaluation of resistivity of concrete in test cylinders using a wenner array probe. Cem. Concr. Res. 26(12):1779-1787. https://doi.org/10.1016/S0008-8846(96)00175-5
Minagawa H, Miyamoto S, Kurashige I, Hisada M. 2023. Appropriate geometrical factors for four-probe method to evaluate electrical resistivity of concrete. Constr. Build. Mater. 374:130784. https://doi.org/10.1016/j.conbuildmat.2023.130784
Garzon AJ, Sanchez J, Andrade C, Rebolledo N, Menéndez E, Fullea J. 2014. Modification of four point method to measure the concrete electrical resistivity in presence of reinforcing bars. Cem. Concr. Compos. 53:249-257. https://doi.org/10.1016/j.cemconcomp.2014.07.013
Tinto Balestra CE, Alessi Reichert T, Pansera WA. 2020. Evaluation of chloride ion penetration through concrete surface electrical resistivity of field naturally degraded structures present in marine environment. Constr. Build. Mater. 230:116979. https://doi.org/10.1016/j.conbuildmat.2019.116979
Chidiac SE, Shafikhani M. 2020. Electrical resistivity model for quantifying concrete chloride diffusion coefficient. Cem. Concr. Compos. 113:103707. https://doi.org/10.1016/j.cemconcomp.2020.103707
Ramezanianpour AA, Pilvar A, Mahdikhani M, Moodi F. 2011. Practical evaluation of relationship between concrete resistivity, water penetration, rapid chloride penetration and compressive strength. Constr. Build. Mater. 25(5):2472-2479. https://doi.org/10.1016/j.conbuildmat.2010.11.069
Robles KPV, Gucunski N, Kee S. 2023. Evaluation of steel corrosion-induced concrete damage using electrical resistivity measurements. Constr. Build. Mater. 411:135412. https://doi.org/10.2139/ssrn.4594115
Sabbağ N, Uyanık O. 2018. Determination of the reinforced concrete strength by apparent resistivity depending on the curing conditions. J. Appl. Geophys. 155:13-25. https://doi.org/10.1016/j.jappgeo.2018.03.007
Cavalcante Araujo C, Rocha Meira G. 2022. Correlation between concrete strength properties and surface electrical resistivity. IBRACON Struct. Mater. J. 15(1). https://doi.org/10.1590/s1983-41952022000100003
Piro NS, Mohammed A, Hamad SM, Kurda R. 2022. Electrical resistivity-Compressive strength predictions for normal strength concrete with waste steel slag as a coarse aggregate replacement using various analytical models. Constr. Build. Mater. 327:127008. https://doi.org/10.1016/j.conbuildmat.2022.127008
Hammond G, Jones C. 2011. Inventory of Carbon & Energy (ICE).
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Consejo Superior de Investigaciones Científicas (CSIC)

This work is licensed under a Creative Commons Attribution 4.0 International License.
© CSIC. Manuscripts published in both the print and online versions of this journal are the property of the Consejo Superior de Investigaciones Científicas, and quoting this source is a requirement for any partial or full reproduction.
All contents of this electronic edition, except where otherwise noted, are distributed under a Creative Commons Attribution 4.0 International (CC BY 4.0) licence. You may read the basic information and the legal text of the licence. The indication of the CC BY 4.0 licence must be expressly stated in this way when necessary.
Self-archiving in repositories, personal webpages or similar, of any version other than the final version of the work produced by the publisher, is not allowed.
Funding data
Universidad de Buenos Aires
Grant numbers PDE 06 2021