El coeficiente de eficacia del humo de sílice

Authors

  • M. Pilar Alaejos Gutiérrez Lab. Central de Estructuras y Materiales del CEDEX
  • M. Fernández Cánovas Lab. Central de Estructuras y Materiales del CEDEX

DOI:

https://doi.org/10.3989/mc.1999.v49.i253.458

Abstract


Silica fume is a pozzolanic addition specially used to get high resistance concrete. Present Spanish standards on additives dictate that silica fumes have to comply with specific requirements when used as concrete addition. Once it has been proved they comply with those requirements, microsilicas of different characteristics can be used, which influence concrete properties in different ways. This paper discloses the experimental results obtained in the Central Laboratory of Structures and Materials of the CEDEX with three microsilicas from different sources. Through the results it has been observed that the coefficient of efficiency of silica fume can have very different values, although complying with the standards in force. The value of this coefficient of efficiency is compared to the one included in text of the future EHE.

Downloads

Download data is not yet available.

Downloads

Published

1999-03-30

How to Cite

Alaejos Gutiérrez, M. P., & Fernández Cánovas, M. (1999). El coeficiente de eficacia del humo de sílice. Materiales De Construcción, 49(253), 57–63. https://doi.org/10.3989/mc.1999.v49.i253.458

Issue

Section

Research Articles